AI Technique

0 / 5. 0

Source:

https://www.youtube.com/watch?v=H_SvuiT3GTk

Duration: 

00:16:19

Year of Production: 

2019

Source/Author: 

Select Sires GenerVations
»«

The level and type of technology determines the quantity and quality of products produced in a given period of time on the farm.

Being the most common method of artificial insemination of cattle, rectal technique require basic skills for about 3 days practice under professional instruction and supervision. Additional proficiency and confidence come with practice on your own.

Technology application

First step is to restrain by running animal to be inseminated into narrow shoot which should be done prior to put semen in the gun and prevent other animals from interfering the process. Use left hand to manipulate reproductive tract, right hand to manipulate insemination gun and avoid surprising animal when approaching it for insemination.

Continue by raising tail with right hand and massage rectum with lubricating glove on left hand and then place tail back side and put fingers together in pointed fashion and insert hand in rectum up to wrist. Gently wipe vulva with paper towel to remove excess manure and with left hand, make a fist and press down directly on top of vulva.

Additionally, remove A.I gun from protective environment ant insert it into vagina at an upward angle of 30 degrees. With gun 6-8 inches inside vagina, slide it until it contacts external portion of cervix. For successful insemination, always know location of gun tip by use of palpating using hand. Remove all manure to avoid palpating interference and then keep open hand flat against flow of rectum . Relax constriction range of cervix by using 2 fingers to massage back and forth.

Locate cervix, straighten it using wrist and remove fluids then slide gun forward and repeat the process. Grasp external opening to cervix with thumb on top and fore fingers underneath to close fornix on top and bottom locate gun tip up to cervical opening by bending and twisting the cervix. When all ranges are passed, rotate glow hand until it lies on top of cervix and raise finger and slowly deposit half of semen. Re check placement then slowly deposit the remaining half of semen.

Push plunger slowly to pour semen into uterine body and after, slowly pull gun from reproductive tract. Finally check gun tip for signs of blood, infection or semen leakage inside sheath and make notes with vet for references then remove sheath from gun and hold it in glove hand. Remove glove starting from upper of arm , remove air from glove, tie it at the open end and dispose off. Clean and return gun to proper store.

 

Sequence from Sequence to Description
00:0000:14Rectal technique is the most common method of A.I of cattle.
00:1500:29Basic A.I skills require about 3 days practice under professional instruction and supervision.
00:3001:43First step in A.I process is to restrain animals to be inseminated.
01:4401:55Use left hand to manipulate reproductive tract and right hand to manipulate insemination gun.
01:5602:35Raise tail with right hand and gently massage rectum with lubricated glove on left hand.
02:3602:50Place tail on back side of left fore arm, put fingers together and insert hand in rectum up to the wrist.
02:5103:03Gently wipe vulva with paper towel to remove excess manure.
03:0403:19With left hand, make a fist and press down directly on top of vulva.
03:2004:54Insert insemination gun in vagina at 30 degrees up ward angle and slide until it contacts external cervix.
04:5506:12Always know location of gun tip and remove all manure as well.
06:1307:01Keep open hand flat against floor of rectum and relax constriction range of cervix.
07:0207:45If cervix is located, push it forward or if not located insert gun tip with thumb and fore fingers.
07:4608:08With straightening motion, milk out fluid and slide gun forward.
08:0809:33The 2 inseminating processes are getting gun to cervix and placing cervix over the gun.
09:3409:52Grasp external opening to cervix with thumb on top fore fingers underneath.
09:5310:44Use palm and 2 fingers to guide gun tip.
10:4511:32Twist and bend cervix and repeat process until all ranges are passed over gun tip.
11:3312:09Rotate glow hand until it lies on top of cervix and pull back gun until you feel the tip.
12:1012:20Raise finger and slowly deposit half of semen and re check placement to deposit remaining semen dose.
12:2113:02Push plunger slowly to pour semen into uterine body
13:0313:29Raise the finger to check gun placement for even semen distribution.
13:3014:38After depositing semen, slowly pull gun from reproductive tract.
14:3914:48Check gun tip for signs of blood and make note with vet for references.
14:4914:53Remove sheath from gun and hold it in glove hand.
14:5415:04Remove glove starting from upper of arm by turning sheath inside glove.
15:0515:12Remove air inside glove and tie its open end to trap sheath manure and dirt inside.
15:1315:22Dispose off used glove and wipe gun clean return it to proper store.
15:2316:19Summary

View external video

By clicking the following link or play button you will leave the FO Video Library and switch to an external website! We would like to see you again, so don’t forget to come back!

Leave a short comment

Leave a Reply

Your email address will not be published. Required fields are marked *